Weld-in thermocouple

To the configurator

Weld-in thermocouple

Fitting with replaceable thermocouple inset

Calculation of the inset length = Protective tube length + Extension pipe length + 10mm

TEMPERATURE LOAD
OPERATING CONDITIONS

Structure of the fitting:

Structure Form 4 in accordance with DIN 43772, shaft diameter 18, 24, 26 or 36 mm, possible shaft lengths 110… 410mm, conical, tapered from Ø 9 to Ø 20 mm depending on the version; Materials: 1.7335 (13CrMo44), 1.7380 (10CrMo910), 1.5415 (15Mo3), 1.4571 (6CrNiMoTi17122); Extension pipe length 165 mm (155), diameter 11 mm in stainless steel. Connection head of light metal Form B according to DIN EN 50446 with cable entry M20x1.5.
(For variants please refer to the worksheet).

Structure of the inset:

Thermocouples 1 (2) x Type “J”, “K”, “N” and Type “S”; basic values in accordance with DIN EN 60584, tolerance class 2; Thermo wires are insulated from each other through a ceramic capillary pipe in accordance with DIN 43725 – in case of precious metal in ceramic material “Ker 799”; alternatively inset in flexible version as mineral insulated sheathed thermocouple inset of 6 or 8 mm diameter of stainless steel or Inconel material. Shelf plate with connection socket.
(For variants please refer to the worksheet).

Types of wiring: