Immersion thermocouple with metal protecive tube

To the configurator

Immersion thermocouple with metal protecive tube

Fitting with replaceable thermocouple inset

Calculation of the inset length = Nominal length + 25mm

TEMPERATURE LOAD
OPERATING CONDITIONS

Structure of the fitting:

BM design according to DIN EN 50446; 15 x 2 mm diameter protective tube made of metal, the BMK version, protective metal tube with an internal protective tube made of ceramic is used for thermocouples type “S”, “B” or “R”. Protective tube is available on request with stop flange or movable clamp connection; see catalogue group “Components”; Connection head of light metal Form B according to DIN EN 50446 with cable entry M20x1.5.
(For variants please refer to the worksheet).

Structure of the inset:

Thermocouples 1(2) x Type “J”, “K”, “N”, “S” and Type “B”; Basic values in accordance with DIN EN 60584, tolerance class 1 or 2, Type “L” according to DIN 43710; The thermo wires are insulated from each other or even from the protective tube through ceramic capillary pipes – in case of precious metal they are made of ceramic “Ker 799”; Alternatively, according to DIN 43735: Flexible version of inset as mineral insulated sheathed thermocouple inset with 6 or 8 mm diameter of stainless steel 1.4541 or Inconel material. Shelf plate with connection socket.
(For variants please refer to the worksheet).

Types of wiring: