Weld-in resistance thermometer

  1. Home
  2. Resistance thermometer
  3. Weld-in resistance thermometers
  4. Weld-in resistance thermometer
To the configurator

EINSCHWEISS-WIDERSTANDSTHERMOMETE

ARMATUR MIT AUSWECHSELBAREM MESSEINSATZ

BERECHNUNG DER MESSEINSATZLÄNGE = SCHUTZROHRLÄNGE + HALSROHRLÄNGE +10M M

Temperaturbelastung
EINSATZBEDINGUNGEN

Structure of the fitting:

Structure Form 4 in accordance with DIN 43772, shaft diameter 18, 24, 26 or 36 mm, possible shaft lengths 110…410 mm, conical, tapered from Ø 9 to Ø 20 mm depending on the version; Materials: 1.7335 (13CrMo44), 1.7380 (10CrMo910), 1.5415 (15Mo3), 1.4571 (6CrNiMoTi17122) Extension pipe length 165 mm (155), diameter 11 mm of stainless steel. Connection head of light metal Form B according to DIN EN 50446 with cable entry M20x1.5.
(For variants please refer to the worksheet).

Structure of the inset in accordance with DIN 43735:

Precision resistor single or dual, Type Pt-100 according to IEC 60751 in tolerance class B or A, connected in 2-, 3- or 4- wire circuit from precision resistor, installed in a rigid inset pipe of stainless steel material or as sheathed resistance thermometer – inset in flexible version with a diameter of 6 mm. Shelf plate with connection socket.
(For variants please refer to the worksheet).

Types of wiring: