Sheathed thermocouple with Lemosa plug

To the configurator

Sheathed thermocouple with Lemosa plug

Flexible version with fixed Lemosa plug

TEMPERATURE LOAD

Structure according to EN 61515:

Thermocouples 1(2) x Type “J”, “K” and “N”, Basic values according to EN 60584, Tolerance class 1 or 2, Type “L” according to DIN 43710, Tolerance class 2, insulated or welded to the ground, completely in flexible version as mineral insulated sheathed cable, insulation of highly compressed magnesium powder.

Sheath material for
Type “J” and “L” made of stainless steel;
Type “K” and “N” made of Inconel

Lemosa plug connected directly to the sheathed cable with gold-plated contacts for sheathed cable diameter:

DMa = 1.5mm Lemo plug – size 0
DMa = 2.0mm Lemo plug – size 0
DMa = 3.0mm Lemo plug – size 1
DMa = 6.0mm Lemo plug – size 1
DMa = 8.0mm Lemo plug – size 2

Diameters and lengths that are not listed can also be delivered.

(For variants please refer to the worksheet).

Design of the thermocouples:

max. recommended temperature load for element type:

Fe-CuNi Type “J”, Fe-CuNi Type “L”, NiCr-Ni Type “K”, NiCrSi-NiSi Type “N”

DMa = 1.5mm 600°C 600°C 900°C 900°C
DMa = 2.0mm 600°C 600°C 900°C 900°C
DMa = 3.0mm 700°C 700°C 1000°C 1000°C
DMa = 6.0mm 700°C 700°C 1000°C 1000°C
DMa = 8.0mm 700°C 700°C 1200°C 1200°C

For very rapid response behaviour, the element can also be welded to the ground; see the section on Special versions or ask our technical customer service.

Types of wiring: