Bayonet Thermocouple

To the configurator

Bayonet Thermocouple

Design with bayonet cap, adjusting spring and connection cable

TEMPERATURE LOAD
OPERATING CONDITIONS

Design:

Thermocouples 1(2, 3) x Type “J”, “K”, “N” and “S”, basic values according to DIN EN 60584, tolerance class 1 or 2, Type “L” according to DIN 43710,
installed in a measurement tip of diameter 3/6 or 8mm made of stainless steel material – also optionally a available with silver tip to achieve an optimal response time.
Nominal length 30mm
The immersion depth or the contact pressure can be changed using the adjusting spring made of steel and the bayonet cap.
Connection: thermoelectric lead 2/4x 0.22qmm, insulation depending on measurement temperature either in silicone, teflon or glass silk, optionally with shielding or with no shielding. For thermoelectric cable lengths KL please refer to the table.

Screw-in nipples are available as accessories in various versions.

(For variants please refer to the worksheet).

Design of the thermocouples:

Max. temperatures according to DIN for materials:

Silicone cable 180°C
Teflon cable 240°C
Glass silk cable 400°C
Glass silk cable (HT) 550°C

Pressures, temperatures and flow rates should be taken into account as per DIN or information in the technical data sheets.