Sheathed thermocouple with thermal plug

To the configurator

Sheathed thermocouple with thermal plug

Flexible version with mounted thermal plug

TEMPERATURE LOAD
OPERATING CONDITIONS

Structure according to EN 61515:

Thermocouples 1(2) x Type “J”, “K” and “N”, Basic values according to EN 60584, Tolerance class 1 or 2; Type “L” according to DIN 43710, Tolerance class 2, insulated or welded to the ground, completely in flexible version as mineral insulated sheathed cable, insulation of highly compressed magnesium powder.

Sheath material for:
Type “J” and “L” made of stainless steel;
Type “K” and “N” made of Inconel

Thermal plug connected directly to the sheathed cable according to DIN EN 50212 with contacts of thermal material for sheathed cable diameter:

DMa = 1.5mm Thermal plug – Mini; flat contacts
DMa = 2.0mm Thermal plug – Mini; flat contacts
DMa = 3.0mm Thermal plug – Mini; flat contacts
DMa = 4.5mm Thermal plug – Standard; round contacts
DMa = 6.0mm Thermal plug – Standard; round contacts

Diameters and lengths that are not listed can also be delivered.
(For variants please refer to the worksheet).

Design of the thermocouples:

max. recommended temperature load for element type:
Fe-CuNi, Type “J” Fe-CuNi, Type “L” NiCr-Ni, Type “K” NiCrSi-NiSi, Type “N”

DMa = 1.5mm 600°C 600°C 900°C 900°C
DMa = 2.0mm 600°C 600°C 900°C 900°C
DMa = 3.0mm 700°C 700°C 1000°C 1000°C
DMa = 6.0mm 700°C 700°C 1000°C 1000°C
DMa = 8.0mm 700°C 700°C 1200°C 1200°C

For very rapid response behaviour, the element can also be welded to the ground; see the section on Special versions or ask our technical customer service.