Multi-level-resistance thermometer, Type “W-M 100 (150,250,450,630 ) FHaKa“ Rigid design with custom-manufactured connection option Possible number of measuring points with single sensor „W-Ma 2016“: Protection sleeve n~ measuring points Lmax./metres Mat. 9.0*1.5mm ≤9 6.0m VA/Inco* 12.0*2.0mm ≤18 6.0m VA/Inco* 12.0*2.5mm ≤13 6.0m VA/Inco* 14.0*2.5mm ≤24 6/3m VA/Inco* 21.3*2.6mm ≤79 12/12m VA/Inco* Protective tube diameter D gem. Tabelle angeben Ø Durchmesser max. protection sleeve length up to process connection Prozessanschluss Nozzle Compression fitting Flange other Protective tube material 1.4301/1.45411.4404/1.4571 2.4816 (Inconel) other Material 1.4301/1.45411.4404/1.4571 2.4816 (Inconel) other Connection box Plastic Aluminium Stainless Steel Protection type IP54 Protection type IP65 other transmitter INOR PR electronic other transmitter-atex ATEX Ex nA ATEX Ex e ATEX Ex ia other Please enter additional information for version with connection boxes here: (Example: number and size or input screwed connections, number and design of required fittings such as plug connections or assembly aid etc.) Nominal length NL: Document measurement point distribution here, or attach enquiry in separate file/sheet. File 1 Browse File 2 Browse File 3 Browse with flange, swivel box with cap nut with threaded nozzle with plug connection optionally instead of connection box with transition dome forrecessed Lemosa coupling directly in dome (box): Lemosa recessed box: Plug Receptacle Size: depending on number of measuring points – specification by KMP optionally instead of a connection box with transition dome inc. extension leads with/without assembled plug system: connected multi-cable: Insulation PVC Silicone Teflon Shielding yes no Ferrules yes no other KLeath length KL=350mm KL=1500mm KL=3000mm other Plug-in connection with: Lemosa Plug Receptacle Harting Plug Receptacle other without plug otherwise only ferrules Temperature load: Measuring point from °C Measuring point to °C environment/connection cable other Sensor Element 1*Pt100 2*Pt100 Pt1000 2*Pt1000 other Tolerance class: class “B“ class “A“ other Circuit technology: 2-conductor 3-conductor 4-conductor Temperature transmitter: Standard HART Profibus Sil 1 Sil 2 other Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Rigid design with custom-manufactured connection option
Prozessanschluss
Please enter additional information for version with connection boxes here: (Example: number and size or input screwed connections, number and design of required fittings such as plug connections or assembly aid etc.)
with flange, swivel box
with cap nut
with threaded nozzle
with plug connection
optionally instead of connection box with transition dome forrecessed Lemosa coupling directly in dome (box):
Size: depending on number of measuring points – specification by KMP
optionally instead of a connection box with transition dome inc. extension leads with/without assembled plug system:
connected multi-cable:
Plug-in connection with:
Privacy policy
Multi-level thermocouple type “T-M 15 (20,25,32,45,54,63) FHaKa“ Protection sleeve n~ measuring points Lmax./metres Mat. 1.5*0.15mm ≤3 3.0m VA/Inco* 2.0*0.2mm ≤7 3.0m VA/Inco* 2.5*0.2mm ≤11 3.0m VA/Inco* 3.0*0.2mm ≤19 10/3m VA/Inco* 3.2*0.2mm ≤23 10/3m VA/Inco* 3.5*0.2mm ≤28 10/3m VA/Inco* 4.0*0.5mm ≤26 25/25m VA/Inco* 4.5*0.5mm ≤36 25/25m VA/Inco* 5.0*0.5mm ≤48 25/25m VA/Inco* 6.35*0.89mm ≤64 25/25m VA/Inco* 7.0*1.0mm ≤77 25/25m VA/Inco* Protective tube diameter D specify according to table Ø diameter max. protection sleeve length up to Process Process connection Nozzle Compression Fitting Flange other protective tube material: 1.4301/1.45411.4404/1.4571 2.4816 (Inconel) other Material 1.4301/1.45411.4404/1.4571 2.4816 (Inconel) other Nominal length NL: Document measuring point distribution here, or attach enquiry in separate file/sheet. File 1 Browse File 2 Browse File 3 Browse Neck tube: with flange with union cap with 2*M16 threaded rods for high adjustment other Connection box Plastic Aluminium Stainless Steel Protection type IP54 Protection type IP65 other Transmitter INOR PR electric other Transmitter-Atex ATEX Ex nA ATEX Ex e ATEX Ex ia other Please enter additional information for version with connection boxes here: (Example: number and size or input screwed connections, number and design of required fittings such as plug connections or assembly aid etc.) optionally instead of connection box with transition dome forConnected Lemosa coupling directly in dome (box): Example with flange with union cap with threaded rods with plug connection Lemosa recessed box: Plug receptacle optionally instead of a connection box with transition dome inc. extension leads with/without assembled plug system: connected thermoelectric lead: Silicone Teflon Glass silk Shielding Ferrules insulation Plug-in connection with thermal thug Mini (flat) Mini (flat) receptacle Standard (round) Standard (round) receptacle without plug; otherwise only ferrules other Plug-in connection with Lemosa plug: Housing size 0 Plug receptable other Temperature load environment/connection cable: Sheathed - thermocouple Fe-CuNi "J"NiCr-Ni "K"NiCrSi-NiSi "N" other Tolerance class: Class "2"Class "1" other Measuring point: welded insulated base welded Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Process connection
optionally instead of connection box with transition dome forConnected Lemosa coupling directly in dome (box):
Example with flange
with union cap
with threaded rods
In starrer Ausführung mit individuell konfektionierbarer Anschlussmöglichkeit
Bitte tragen Sie hier weitere Informationen für Variante mit Anschlusskasten ein: (Beispiel: Anzahl und Größe von Eingangsverschraubungen, Anzahl und Ausführung gewünschter Aufbauten wie Steckverbindungen oder Montagehilfen etc.)
Bsp. mit Flansch, Kasten drehbar
Bsp. mit Überwurfmutter
Bsp. mit Gewindestutzen
Bsp. mit Steckeranschluß
wahlweise statt eines Anschlußkastens mit Übergangsdom für direkt im Dom verbaute Lemosa-Einbau-Kupplung (Dose):
Größe: in Abhängigkeit von der Messstellenanzahl – Vorgabe erfolgt durch KMP
wahlweise statt eines Anschlußkastens mit Übergangsdom inkl. Verlängerungsleitungen mit/ohne konfektionierten Steckersystem:
angeschlossene Multikabel:
Steckverbindung mit:
Datenschutzerklärung
Klassisches Stufen-Thermoelement Stufen-Thermoelement Typ“T-M 15 (20,25,32,45,54,63) FHaKa“ Schutzrohr n~ Messpunkte Lmax./Meter Wst. 1.5*0.15mm ≤3 3.0m VA/Inco* 2.0*0.2mm ≤7 3.0m VA/Inco* 2.5*0.2mm ≤11 3.0m VA/Inco* 3.0*0.2mm ≤19 10/3m VA/Inco* 3.2*0.2mm ≤23 10/3m VA/Inco* 3.5*0.2mm ≤28 10/3m VA/Inco* 4.0*0.5mm ≤26 25/25m VA/Inco* 4.5*0.5mm ≤36 25/25m VA/Inco* 5.0*0.5mm ≤48 25/25m VA/Inco* 6.35*0.89mm ≤64 25/25m VA/Inco* 7.0*1.0mm ≤77 25/25m VA/Inco* Schutzrohrdurchmesser D gem. Tabelle angeben Ø Durchmesser max. Schutzrohrlänge bis zum Prozessanschluss Prozessanschluss Stutzen Verschraubung Flansch andere Schutzrohrwerkstoff 1.4301/1.45411.4404/1.4571 2.4816 (Inconel) andere Werkstoff 1.4301/1.45411.4404/1.4571 2.4816 (Inconel) andere Nennlänge NL: Messstellenverteilung hier dokumentieren, oder in separater Datei/Blatt Ihrer Anfrage beifügen. Anlage 1 Browse Anlage 2 Browse Anlage 3 Browse halsrohr mit Flansch mit Überwurfmutter mit 2*M16 Gewindestangen zur Höhenverstellung Halsrohr mit 2*M16 Gewindestangen zur Höhenverstellung anschlusskasten Kunststoff Aluminium Edelstahl Schutzart IP54 Schutzart IP65 andere Transmitter INOR PR electronics andere Transmitter-Atex ATEX Ex nA ATEX Ex e ATEX Ex ia andere Bitte tragen Sie hier weitere Informationen für Variante mit Anschlusskasten ein (Beispiel: Anzahl und Größe von Eingangsverschraubungen, Anzahl und Ausführung gewünschter Aufbauten wie Steckverbindungen oder Montagehilfen etc.) wahlweise statt eines Anschlußkastens mit Übergangsdom für direkt im Dom verbaute Lemosa-Einbau-Kupplung (Dose): Bsp. mit Flansch mit Überwurfmutter Gewinderstangen Steckeranschluß Lemosa-Einbau-Dose Stecker Kupplung wahlweise statt eines Anschlußkastens mit Übergangsdom inkl. Verlängerungsleitungen mit/ohne konfektioniertem Steckersystem: angeschlossene Thermoleitung Silikon Teflon Glasseide Aderendhülsen isolation Steckverbindung mit Thermo-Stecker Mini (flach) Stecker Mini (flach) Kupplung Standard (rund) Stecker ohne Stecker, sondern nur Aderenhülsen Andere Steckverbindung mit Lemosa-Stecker: Gehäuse Größe 0 Größe 1 Stecker Kupplung Andere Temperaturbelastung Meßstelle von - bis °C Umgebung/Anschlußleitung Mantel-Thermoelement Fe-CuNi "J"NiCr-Ni "K"NiCrSi-NiSi "N" Andere Toleranzklasse Klasse "2"Klasse "1" Andere Meßstelle isoliert verschweißtbodenverschweißt Zusatz / Bemerkungen Firma / Absender * Anrede * FrauHerrDivers Ansprechpartner * Straße / Ort * Telefon * Fax E-Mail * Ihre Ref.-Nr. Stückzahl Alternative mgl. Lieferzeit Datenschutz * Ich bestätigte, die Informationen zur Datenerfassung durch Nutzung dieses Formulars zur Kenntnis genommen zu haben. Die von KMP durch dieses Formular erfassten Daten dienen ausschließlich zur Bearbeitung meiner Anfrage. Ich kann die Löschung meiner Daten jederzeit von KMP verlangen. Datenschutzerklärung Anfrage senden
Bsp. mit Flansch
mit Überwurfmutter
Gewinderstangen
Steckeranschluß
Eintauch-Widerstandsthermometer Armatur mit auswechselbarem Widerstandsthermometer-Meßeinsatz Berechnung der Meßeinsatzlänge = Nennlänge +25mm Schutzrohrdurchmesser D 9 x 1.0mm 11 x 1.0mm 11 x 2.0mm 12 x 1,5mm 15 x 3.0mm andere Prozeßanschluß Anschlagflansch (nach DIN 43734, aus GG) Gegenflansch (nach DIN43734, aus Stahl) G1/2" Klemmverschraubung "GEV" aus 1.4571 (V4A) G1" Klemmverschraubung "GEV" aus Stahl andere Nennlänge NL 180mm 250mm 355mm 500mm andere Temperaturbelastung Meßstelle: von (°C) Meßstelle: bis (°C) Umgebung/Anschlußkopf (°C) Toleranzklasse Klasse "B" Klasse "A" andere Schutzrohrwerkstoff Stahl St. 35.8 1.4571 (V4A) Edelstahl teflonisiert hochwarmfest 1.4762 hochwarmfest 1.4841 andere Innenschutzrohr Keramik Typ "610" Keramik Typ "799" andere Anschlußkopf Form A: Leichtmetall Form B: Leichtmetall andere Mantelwiderstandsthermometer-Messeinsatz Pt-100 einfach Pt-100 doppelt Pt-1000 einfach Pt-1000 doppelt 2-Leiterschaltung 3-Leiterschaltung 4-Leiterschaltung andere Einsatzbedingungen Temperatur Medium Druck Zusatz / Bemerkungen Firma / Absender * Anrede * FrauHerrDivers Ansprechpartner * Straße / Ort * Telefon * Fax E-Mail * Ihre Ref.-Nr. Stückzahl Alternative mgl. Lieferzeit Datenschutz * Ich bestätigte, die Informationen zur Datenerfassung durch Nutzung dieses Formulars zur Kenntnis genommen zu haben. Die von KMP durch dieses Formular erfassten Daten dienen ausschließlich zur Bearbeitung meiner Anfrage. Ich kann die Löschung meiner Daten jederzeit von KMP verlangen. Datenschutzerklärung Anfrage senden
Große Eintauch-Thermoelemente Typ AM / AMK Form AM (AMK) nach DIN EN 50446 Berechnung der Drahtlänge = Nennlänge +40mm unedel (+80mm edel) Schutzrohrdurchmesser D 22mm 26mm andere Nennlänge NL 500mm 710mm 1000mm 1400mm andere Prozessanschluss Anschlagflansch (nach DIN 43734, aus GG) [vc_single_image image="466" img_size="full" onclick="link_image"] Gegenflansch (nach DIN 43734, aus Stahl) G1" Klemmverschraubung "GEV" aus Stahl [vc_single_image image="467" img_size="full" onclick="link_image"] andere Thermoelement-Meßeinsatz NiCr-Ni "K" einfach NiCr-Ni "K" doppelt Fe-CuNi "J" einfach Fe-CuNi "J" doppelt NiCrSi-NiSi "N" einfach NiCrSi-NiSi "N" doppelt PtRh-Pt "S" einfach PtRh-Pt "S" doppelt PtRh-Pt "R" einfach PtRh-Pt "R" doppelt PtRh-Pt "B" einfach PtRh-Pt "B" doppelt andere Temperaturbelastung Meßstelle: von (°C) Meßstelle: bis (°C) Umgebung/Anschlußkopf (°C) Schutzrohrwerkstoff Stahl St. 35.8 1.4571 (V4A) Edelstahl teflonisiert hochwarmfest 1.4762 hochwarmfest 1.4841 andere Innenschutzrohr Keramik Typ "610" Keramik Typ "799" andere Anschlusskopf Form A Leichtmetall Form B Leichtmetall andere Toleranzklasse Klasse "2" Klasse "1" andere Zusatz / Bemerkungen Firma / Absender * Anrede * FrauHerrDivers Ansprechpartner * Straße / Ort * Telefon * Fax E-Mail * Ihre Ref.-Nr. Stückzahl Alternative mgl. Lieferzeit Datenschutz * Ich bestätigte, die Informationen zur Datenerfassung durch Nutzung dieses Formulars zur Kenntnis genommen zu haben. Die von KMP durch dieses Formular erfassten Daten dienen ausschließlich zur Bearbeitung meiner Anfrage. Ich kann die Löschung meiner Daten jederzeit von KMP verlangen. Datenschutzerklärung Anfrage senden
Eintauch-Thermoelement Armatur mit auswechselbarem Meßeinsatz Berechnung der Meßeinsatzlänge = Nennlänge +25mm Schutzrohrdurchmesser D 9 x 1.0mm 11 x 1.0mm 11 x 2.0mm 12 x 1,5mm 15 x 3.0mm andere Schutzrohrwerkstoff Stahl St. 35.8 1.4571 (V4A) Edelstahl teflonisiert hochwarmfest 1.4762 hochwarmfest 1.4841 andere Prozessanschluss Anschlagflansch (nach DIN 43734, aus GG) Gegenflansch (nach DIN43734, aus Stahl) G1/2" Klemmverschr. "GEV" aus 1.4571 (V4A) G1" Klemmverschraubung "GEV" aus Stahl andere Toleranzklasse Klasse "2" Klasse "1" andere Temperaturbelastung Meßstelle: von (°C) Meßstelle: bis (°C) Umgebung/Anschlußkopf (°C) Nennlänge NL 180mm 250mm 355mm 500mm andere Innenschutzrohr Keramik Typ "610" Keramik Typ "799" andere Anschlusskopf Form A Leichtmetall Form B Leichtmetall andere Thermoelement-Meßeinsatz NiCr-Ni "K" einfach NiCr-Ni "K" doppelt Fe-CuNi "J" einfach Fe-CuNi "J" doppelt NiCrSi-NiSi "N" einfach NiCrSi-NiSi "N" doppelt PtRh-Pt "S" einfach PtRh-Pt "S" doppelt PtRh-Pt "R" einfach PtRh-Pt "R" doppelt PtRh-Pt "B" einfach PtRh-Pt "B" doppelt Fe-CuNi "L" einfach Fe-CuNi "L" doppelt andere Einsatzbedingungen Temperatur Medium Druck Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Large immersion thermocouple Type AM / AMK Calculation of the wire length = Nominal length + 40mm base metal (+ 80mm precious) Calculation of the wire length = Nominal length + 40mm base metal (+ 80mm precious) Protective tube dia D 22mm 26mm others Nominal length NL 500mm 710mm 1000mm 1400mm others Process connection: Stop flange (acc. to DIN 43734, made of GG) [vc_single_image image="466" img_size="full" onclick="link_image"] Counter flange (acc. to DIN 43734, made of steel G1" clamp connection "GEV" of steel [vc_single_image image="467" img_size="full" onclick="link_image"] others Thermocouple inset NiCr-Ni "K" single NiCr-Ni "K" dual Fe-CuNi "J" single Fe-CuNi "J" dual NiCrSi-NiSi "N" single NiCrSi-NiSi "N" dual PtRh-Pt "S" single PtRh-Pt "S" dual PtRh-Pt "R" single PtRh-Pt "R" dual PtRh-Pt "B" single PtRh-Pt "B" dual others Temperature load Measurement point: from (°C) Measurement point: to (°C) Environment/Connection head (°C) Protective tube material Steel St. 35.8 1.4571 (V4A) Stainless steel teflonised highly heat resistant 1.4762 highly heat resistant 1.4841 others Internal protective tube Ceramic Type "610" Ceramic Type "799" others Connection head Form A: Light metal Form B: Light metal others Tolerance class class "2" class "1" others Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Immersion thermocouple with metal protecive tube Fitting with replaceable thermocouple inset Calculation of the inset length = Nominal length + 25mm Protective tube dia D 9 x 1.0mm 11 x 1.0mm 11 x 2.0mm 12 x 1.5mm 15 x 3.0mm others Nominal length NL 180mm 250mm 355mm 500mm others Prozessanschluss Stop flange (acc. to DIN 43734, made of GG) [vc_single_image image="466" img_size="full" onclick="link_image"] Counter flange (acc. to DIN 43734, made of steel G1/2" clamp connection "GEV" of 1.4571 (V4A) G1" clamp connection "GEV" of steel [vc_single_image image="467" img_size="full" onclick="link_image"] others Thermocouple inset NiCr-Ni "K" single NiCr-Ni "K" dual Fe-CuNi "J" single Fe-CuNi "J" dual NiCrSi-NiSi "N" single NiCrSi-NiSi "N" dual PtRh-Pt "S" single PtRh-Pt "S" dual PtRh-Pt "R" single PtRh-Pt "R" dual PtRh-Pt "B" single PtRh-Pt "B" dual Fe-CuNi "L" single Fe-CuNi "L" dual others Temperature load Measurement point: from (°C) Measurement point: to (°C) Environment/Connection head (°C) Protective tube material Steel St. 35.8 1.4571 (V4A) Stainless steel teflonised highly heat resistant 1.4762 highly heat resistant 1.4841 others Internal protective tube Ceramic Type "610" Ceramic Type "799" others Connection head Form A: Light metal Form B: Light metal others Tolerance class class "2" class "1" others Operating conditions Temperature Medium Pressure Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Large straight thermocouples Form AK (AKK) acc. to DIN EN 50446 Calculation of the inset length = Nominal length + 40mm base metal (+ 80mm precious) Protective tube dia D 24 x 2,5mm (only for KER 610) 24 x 3.0mm (only for KER 799) 26 x 3.0mm (only for KER 530) others Internal protective tube yes Process connection Stop flange (acc. to DIN 43734, made of GG) [vc_single_image image="466" img_size="full" onclick="link_image"] Counter flange (acc. to DIN 43734, made of steel G1" clamp connection "GEV" of steel [vc_single_image image="467" img_size="full" onclick="link_image"] others Connection head Form A: Light metal Form B: Light metal others Thermocouple inset NiCr-Ni "K" single NiCr-Ni "K" dual NiCrSi-NiSi "N" single NiCrSi-NiSi "N" dual PtRh-Pt "S" single PtRh-Pt "S" dual PtRh-Pt "B" single PtRh-Pt "B" dual PtRh-Pt "R" single PtRh-Pt "R" dual others Protective tube material Ceramic Type "610" Ceramic Type "799" Ceramic Type "530" andere Nominal length NL 500mm 710mm 1000mm 1400mm others Neck tube HL Diameter 32 x 200mm others Temperature load Measurement point: from (°C) Measurement point: to (°C) Environment/Connection head (°C) Tolerance class class "2" class "1" others Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Screw-in thermocouple Fitting with replaceable thermocouple-inset Protective tube Dia 6 x 1.0mm 9 x 1.0mm 11 x 1.0mm 11 x 2.0mm 14 x 2.5mm others Protective tube length NL 160mm 250mm 400mm others Screw neck material 1.4541 (V2A) 1.4571 (V4A) others Connection head Form A: Light metal [vc_single_image image="469" img_size="full" onclick="link_image"] Form B: Light metal [vc_single_image image="470" img_size="full" onclick="link_image"] others: Light metal Thermocouple inset 1 x NiCr-Ni "K" 2 x NiCr-Ni "K" 1 x Fe-CuNi "J" 2 x Fe-CuNi "J" 1 x NiCrSi-NiSi "N" 2 x NiCrSi-NiSi "N" 1 x Fe-CuNi "L" 2 x Fe-CuNi "L" others Operating conditions Temperatur Medium Pressure Screw neck G 1⁄2“ G 1“ others Tube material 1.4541 (V2A) 1.4541 (V2A) others Extension pipe length HL 145mm others Temperature load Measurement point: from (°C) Measurement point: to (°C) Environment/Connection head (°C) Tolerance class class 2 class 1 others Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Flanged thermocouple Fitting with replaceable thermocouple inset Calculation of the inset length = Protective tube length + Extension pipe length + 10mm Protective tube diameter D 11 x 2.0mm 14 x 2.5mm others Flange DN25/PN40 Form C DN40/PN16 Form C others Nominal length NL 160mm 250mm 400mm others Alternatively / resistant to acids and alkalis Hasteloy C Tantalum Titanium Nickel Teflon others Temperature load Measuring point: from (°C) Measuring point: to (°C) Environment/Connection head (°C) Tolerance class class "2" class "1" others Protective tube material 1.4541 (V2A) 1.4571 (V4A) others Material of flange 1.4541 (V2A) 1.4571 (V4A) others Extension pipe length HL 82mm 145mm others Connection head Form A: Light metal Form B: Light metal others Thermocouple inset NiCr-Ni "K" single NiCr-Ni "K" dual Fe-CuNi "J" single Fe-CuNi "J" dual NiCrSi-NiSi "N" single NiCrSi-NiSi "N" dual PtRh-Pt "S" single PtRh-Pt "S" dual Fe-CuNi "L" single Fe-CuNi "L" dual others Operating conditions Temperature Medium Pressure Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Sheathed thermocouple with thermal plug Flexible version with mounted thermal plug Sheath diameter DMa 0.5mm 1.5mm 3.0mm 4.5mm 6.0mm others Nominal length NL 100mm 300mm 500mm 1000mm 2000mm others Plug temperature 200°C 350°C 650°C (only standard with round contacts) others Sheathed thermocouple NiCr-Ni "K" single NiCr-Ni "K" dual Fe-CuNi "J" single Fe-CuNi "J" dual NiCrSi-NiSi "N" single NiCrSi-NiSi "N" dual Fe-CuNi "L" single Fe-CuNi "L" dual PtRh-Pt "S" single PtRh-Pt "S" dual PtRh-Pt "R" single PtRh-Pt "R" dual others Measuring point welded insulated ground welded andere Sheath material 1.4541 (V2A) 2.4816 (Inconel 600) others Plug connector Size Mini with flat contacts (up to DMa=3.0mm) Standard with round contacts (from DMa=3.0mm) single (1 element) dual (2 elements) others Temperature load Measurement point: from (°C) Measurement point: to (°C) Environment / Plug (°C) Operating conditions Temperature Medium Pressure Tolerance class class "2" class "1" andere Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Sheathed thermocouple with Lemosa plug Flexible version with fixed Lemosa plug Sheath diameter DMa 0.5mm 1.5mm 3.0mm 4.0mm 6.0mm others Nominal length NL 100mm 300mm 500mm 1000mm 2000mm others Pin assignment Lemosa plug Lemosa coupling Protection rating IP68 (otherwise IP54) others Sheathed thermocouple NiCr-Ni "K" single NiCr-Ni "K" dual Fe-CuNi "J" single Fe-CuNi "J" dual NiCrSi-NiSi "N" single NiCrSi-NiSi "N" dual Fe-CuNi "L" single Fe-CuNi "L" dual PtRh-Pt "S" single PtRh-Pt "S" dual PtRh-Pt "R" single PtRh-Pt "R" dual others Sheath material 1.4541 (V2A) 2.4816 (Inconel 600) others Lemosa plug connection Size 00 Size 0 Size 1 Size 2 2 Pins 4 Pins 6 Pins 8 Pins Contacts gold plated made of element material Temperature load Measurement point: from (°C) Measurement point: to (°C) Environment/Connector Tolerance class class "2" class "1" others Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Sheathed thermocouple with cable Flexible version with connected compensating cable Sheath diameter DMa 0.5mm 1.5mm 3.0mm 4.0mm 6.0mm others Connecting plug Mini plug Standard plug Mini coupling Standard coupling Lemosa plug Lemosa coupling Size 00 Size 0 Size 1 Size 2 2polig 4polig 6polig Plus pole on socket Plus pole on pin Temperature load Measurement point: from (°C) Measurement point: to (°C) Environment/Connection cable (°C) Tolerance class class "2" class "1" others Sheath material 1.4541 (V2A) 2.4816 (Inco) others Nominal length NL 100mm 300mm 500mm 1000mm 2000mm others Sheathed thermocouple NiCr-Ni "K" single NiCr-Ni "K" dual Fe-CuNi "J" single Fe-CuNi "J" dual NiCrSi-NiSi "N" single NiCrSi-NiSi "N" dual Fe-CuNi "L" single Fe-CuNi "L" dual PtRh-Pt "S" single PtRh-Pt "S" dual PtRh-Pt "R" single PtRh-Pt "R" dual others Measuring point welded insulated ground welded others Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Angle type thermocouple Armatur mit auswechselbarem Thermoelement-Meßeinsatz Berechnung der Meßeinsatzlänge = Nennlänge +15mm Schutzrohr Stahl emailliert, D=22 * 500mm, max. 600°C Reineisen, D=26 * 500mm, max. 550°C Reineisen, D=26 * 500mm, max. 1200°C Silizium Carbit nitriert, D=25*500mm, max.1200°C Silizium Carbit nitriert, D=40*500mm, max.1200°C andere Winkel Winkelstück + Halterohr gerade Anschlag + Halterohr gebogen ohne Anschlag, nur gebogen andere Anschlußkopf Form A: Leichtmetall Form B: Leichtmetall andere Thermoelement-Meßeinsatz NiCr-Ni "K" einfach NiCr-Ni "K" doppelt Fe-CuNi "J" einfach Fe-CuNi "J" doppelt NiCrSi-NiSi "N" einfach NiCrSi-NiSi "N" doppelt PtRh-Pt "S" einfach PtRh-Pt "S" doppelt PtRh-Pt "R" einfach PtRh-Pt "R" doppelt PtRh-Pt "B" einfach PtRh-Pt "B" doppelt andere Einsatzbedingungen Temperatur Medium Druck Halterohr 500mm 710mm 1000mm andere Prozeßanschluß Anschlagflansch (nach DIN 43734, aus GG) Gegenflansch (nach DIN43734, aus Stahl) G1" Klemmverschraubung "GEV" aus Stahl andere Temperaturbelastung Meßstelle: von (°C) Meßstelle: bis (°C) Umgebung/Anschlußleitung (°C) Toleranzklasse Klasse 2 Klasse 1 andere Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Cable thermocouple with plug Insulated wire thermocouples in flexible version with miniature thermal plugr Structure and insulation material Teflon-single strands; twisted; D=approx. 2.0mm Teflon / Teflon; D= approx. 3.0mm Teflon / Wire / Teflon; D=approx. 3,0mm Glass silk / Glass silk; D=approx. 3.0mm Glass silk / Glass silk / Wire; D=approx. 3.5mm Teflon / Silikone; D = approx. 3.5mm Silicone / Silicone; D=approx. 4.5mm others Plug-in connection Size Mini with flat contacts (up to diameter DMa Standard with round contacts (from diameter DMa= Plug temperature 200 °C Plug temperature 350 °C Plug temperature 650 °C single (1 element) dual (2 elements) Sheathed thermocouple NiCr-Ni "K" single NiCr-Ni "K" dual Fe-CuNi "J" single Fe-CuNi "J" dual Fe-CuNi "L" single Fe-CuNi "L" dual others Measuring point welded insulated junction bare ground welded others Nominal length NL 100mm 300mm 500mm 1000mm 2000mm others Temperature load Measurement point: from (°C) Measurement point: to (°C) Environment / Plug (°C) Tolerance class class "2" class "1" others Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Bayonet Thermocouple Design with bayonet cap, adjusting spring and connection cable Protective tube Dia 3.0mm 6.0mm 8.0mm others Nominal length NL 30mm others Design of tip flat smooth made of stainless steel with tip of stainless steel with silver tip of 10mm length for particularly others Cable material Silicone Teflon Glass silk up to 400°C Glass silk up to 550°C others Thermocouple inset 1 x NiCr-Ni 2 x NiCr-Ni 1 x Fe-CuNi 2 x Fe-CuNi 1 x NiCrSi-NiSi 2 x NiCrSi-NiSi 1 x Fe-CuNi "L" 2 x Fe-CuNi "L" others Operating conditions Temperature Medium Pressure Tube material 1.4571 (V4A) others Bayonet cap for 10mm nipple for 12mm nipple others Spring adjustment range FL = 180mm FL = 200mm FL = 350mm others Temperature load Measurement point: from (°C) Measurement point: to (°C) Environment/Connection head (°C) Tolerance class class 2 class 1 others Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Magnet surface thermocouple with cable Thermoelectric lead Insulation Silicone Insulation Teflon Insulation Glas silk Shielded Yes Shielded No Cable ends tin plated Cable end sleeves others Plug-in connection with thermal plug Mini plug Standard plug Plug Couplingothers others Temperature load Measurement point: from (°C) Measurement point: to (°C) Environment/Connector (°C) Tolerance class class "2" class "1" others Cable length KL = 170mm KL = 500mm KL = 1000mm others Connection with Lemosa plug Size 0 Size 1 Plug Coupling Sheath thermocouple NiCr-Ni "K" single Fe-CuNi "J" single NiCrSi-NiSi "N" single Fe-CuNi "L" single others Operating conditions Temperature Medium Pressure Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Surface – Sheathed Thermocouple with connection cable Version with surface-receivers and connected sheathed and compensation cable Measurement value reception Cu-Block 10*5*40mm Cu-sheet 15*1*30mm others Thermoelectric lead Insulation Silicone Insulation Teflon Insulation Glas silk Shielded Yes Shielded No Cable end sleeves others Plug connection with thermal plug Mini plug (up to DMa = 3mm dia) Standard with round contacts (from DMa=3.0mm) Plug Coupling others Temperature load Measurement point: from (°C) Measurement point: to (°C) Environment/Connector (°C) Tolerance class class "2" class "1" others Sheathed cable Diameter DMa = 3.0mm others Nominal length NL = 500mm other nominal length Cable length KL = 170mm KL = 500mm KL = 1000mm others Plug connection with Lemosa plug Size 0 Size 1 Plug Coupling Sheathed thermocouple NiCr-Ni "K" single Fe-CuNi "J" single NiCrSi-NiSi "N" single Fe-CuNi "L" single others Operating conditions Temperature Medium Pressure Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Pipe mounted thermocouple with connection cable Measurement value reception Measurement value reception VA-Block 6*6*30m Cu-Block 6*6*30mm Ms-Block 6*6*30mm others Radius R12 Radius R20 Rohr 1/4" Rohr 1/2" others Cable length KL = 500mm KL = 1000mm KL = 2500mm others Mantel-Thermoelement NiCr-Ni "K" single NiCr-Ni "K" dual Fe-CuNi "J" single Fe-CuNi "J" dual NiCrSi-NiSi "N" single NiCrSi-NiSi "N" dual Fe-CuNi "L" single Fe-CuNi "L" dual others Operating conditions Temperature Medium Pressure Thermoelectric lead Insulation Silicone Insulation Teflon Insulation Glas silk Shielded Yes Shielded No Cable end sleeves Cable ends tin plated others Temperature load Measurement point: from (°C) Measurement point: to (°C) Environment/Connection cable (°C) Tolerance class class "2" class "1" others Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Thermocouple inset Calculation of the inset length = Protective tube length + Extension pipe length + 10mm Design rigid (pipe) flexible (sheathed cable) Pipe diameter D 3.0mm 4,0mm 6.0mm others Meßeinsatzlänge MEL 275mm 315mm 375mm 405mm 435mm 555mm others Thermocouplet NiCr-Ni "K" single NiCr-Ni "K" dual Fe-CuNi "J" single Fe-CuNi "J" dual NiCrSi-NiSi "N" single NiCrSi-NiSi "N" dual Fe-CuNi "L" single Fe-CuNi "L" dual PtRh-Pt "S" single PtRh-Pt "S" dual PtRh-Pt "R" single PtRh-Pt "R" dual others Measuring point welded insulated ground welded Material 1.4301 (V2A) 1.4541 (V2A) for flexible version 2.4816 (Inconel 600) others Sheath diameter DMa (flexible version) 0.5mm 1.5mm 3.0mm 4.0mm 6.0mm others Temperature load Measuring point: from (°C) Measuring point: to (°C) Environment/plug-in socket: (°C) Tolerance class class "2" class "1" others Operating conditions Temperature Medium Pressure Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Multipoint thermocouple Mineral insulated version – flexible Typ “T-Ma 950 Hka 10x“ real Measuring point Please enter here from the table one central wire Please enter here from the table no. of measuring points Please enter here from the table other no. of measuring points other Ø (mm) L1 L2 L3 L4 L5 L6 L7 L8 L9 L10 L11 L12 L13 L14 L15 L16 L17 L18 L19 L20 L21 NL (mm) = material 1.4541 (V2A) 1.4571 (V4A)2.4816 (Inco) 2.4816 (Inco) other connection cable PTFE / wire / PTFE single wires PTFE other lenght (mm) Temperature load Measurement point: from °C Measurement point: to °C Environment/Connection cable °C Thermocouple NiCr-Ni "K" NiCrSi-NiSi "N" Certificates Material certificate 3.1 Test calibration certificate Others Additional specification/ Remarks Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Pipe mounted resistance thermometer with connection cable Version with surface receiver box and connected extension cable Measurement value reception VA-Block 6*6*30mm Cu-Block 6*6*30mm Ms-Block 6*6*30mm others Radius R12 Radius R20 Pipe 1/4" Pipe 1/2" others Cable length KL = 500mm KL = 1000mm KL = 2500mm others Sensor element Pt-100 single Pt-100 dual Pt-1000 single Pt-1000 dual Ni-100 single Ni-100 dual Ni-1000 single Ni-1000 dual others Connection cable Insulation Silicone Insulation Teflon Insulation Glas silk Shielded Yes Shielded No Cable end sleeves Cable ends tin plated others Temperature load Measurement point: from (°C) Measurement point: to (°C) Environment/Connection cable (°C) Tolerance class: class "A" class "B" others Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Immersion resistance thermometer Fittings with replaceable resistance thermometer inset Calculation of the inset length = Nominal length + 25mm Protective tube dia D 9 x 1.0mm 11 x 1.0mm 11 x 2.0mm 12 x 1,5mm 15 x 3.0mm others Process connection Stop flange (acc. to DIN 43734, made of GG) Counter flange (acc. to DIN 43734, made of steel G 1/2" clamp connection “GEV” of 1.4571 (V4A) G 1" clamp connection “GEV” of 1.4571 (V4A) others Nominal length NL 180mm 250mm 355mm 500mm others Temperature load Measurement point: from (°C) Measurement point: to (°C) Environment/Connection head (°C) Tolerance class class "B" class "A" others Protective tube material Steel St. 35.8 1.4571 (V4A) Stainless steel teflonised highly heat resistant 1.4762 highly heat resistant 1.4841 others Internal protective tube Ceramic Type "610" Ceramic Type "799" andere Connection head Form A: Light metal Form B: Light metal others Sheath resistance thermometer inset Pt-100 single Pt-100 dual Pt-1000 single Pt-1000 dual 2-wire circuit 3-wire circuit 4-wire circuit others Operating conditions Temperature Medium Pressure Comments Company * Title * MrsMrDivers Name * Address * Phone * Fax E-mail * References Quantity Delivery time Alternatives Privacy policy * I confirmed that I have taken note of the information on data collection by using this form. The data collected by KMP through this form will be used exclusively to process my request. I can request the deletion of my data from KMP at any time. Privacy policy Send request
Screw-in Resistance thermometer Fitting with replaceable resistance thermometer inset Calculation of the inset length = Protective tube length + Extension pipe length + 10mm Protective tube dia D 6 x 1.0mm 9 x 1.0mm 11 x 1.0mm 11 x 2.0mm 14 x 2,5mm others Screw neck G 1/2" G 1 others Protective tube length NL 100mm